Home > ELECTRICAL > ROUGH ELECTRICAL > PANEL BOXES
Choose a sub category:
SAFETY SWITCHES METER BASES
Sort By:
1 2 3 ... 7
Cutler Hammer BRFPP Filler Plate GE THFILLER Rectangle Filler Plate GROUND BAR 7 HOLE CONSUMER PK
Plastic (snap-in) for type BR 1 in space. May also be used with 400 and 600 A load centers. GE Filler Plate Kit, 6-7/8 in Length, 2-7/8 in Width, 3/4 in Height For grounding copper or aluminum terminals in a GE load center. Offers 4 small holes for 14 to 8 AWG copper or 12 to 8 AWG aluminum terminals and 3 large holes for 14 to 4 AWG copper or 12 to 4 AWG aluminum terminals. UL listed and ANSI certified. 6-7/8 in H x 2-7/8 in W x 1/2 in depth, 0.105 lb.
Cutler-Hammer GBK10P Ground Bar Kits LUG KIT NO6-2/0 NEUTRAL/GROUND Cutler-Hammer GBK14P Ground Bar Kits
Cutler-Hammer Ground Bar Kit, 10 Terminals, 4.7 in Length, 2.3 in Width, 1/2 in Height For use with wire range 6-2/0. Can be mounted on any neutral or ground position by simply removing the termination screw. UL listed. 2-7/8 in H x 3/4 in W x 6-7/8 in D, 0.07 lb. Eaton Ground Bar Kit, Number of Terminals: 14, Wire Size: 14 to 4 AWG, 5.69 in L
Square D PK4GTACP Ground Bar Kits Square D QOFPCP Filler Plate Square D QO70AN Auxiliary Neutral Lug Kit
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed. Fills opening in covers if twist out is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL listed and ANSI Certified. Made for QO load centers. Field installed for number 12 to 2 Al or number 14 to 4 Cu wire. QO accessories can only be used with QO load centers.
Square D HOMFPCP Filler Plate Square D PK7GTACP Ground Bar Kits GROUND BAR 24 HOLE PM-GOLD PK
Fills opening in covers if twist out is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL listed and ANSI Certified. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed. Used for additional grounding as required by local code. Compatible with most load center enclosures. Fits solid or stranded 4 - 14 copper wire and 10 - 12 aluminum wire. Includes mounting screws. UL listed and ANSI certified. 11 in H x 3-1/2 in W x 1/2 in D, 0.304 lb.
Square D HOM100AN Neutral Lug Kit Schneider PK9GTACP Ground Bar Kit Siemens Energy ECGB10 Ground Bar Kits
Breaker box neutral lug is designed for Homeline load centers. It works with number 1 to 1/0 copper and aluminum wire. UL listed and ANSI certified. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed. For equipment grounding provision. #14 to 4 AWG, 60/75 deg Celsius, Cu/A1.
Siemens EC38595 Closure Plate Square D ACPCP Closing Plate Square D PK15GTACP Ground Bar Kits
Siemens Closure Plate, 3/4 in Nominal, Dimensions: 12.8 X 5.2 X 3.7 in Used for sealing off a hub opening when a service feed originates underground. The plate is compatible with A-type openings and can be used on outdoor devices that utilize a 4-hole mounting pattern. Use for A-size hub opening for Square D metering equipment. UL and CSA listed. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
Square D PK12GTACP Ground Bar Kits Schneider PK18GTACP Ground Bar Kit Square D PK23GTACP Ground Bar Kits
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
Siemens EC2GB152 Ground Bar Kit With Terminal 2/0 Lug Eaton DPU222RP Type ACD Non-Fusible Pullout Disconnect Switch GE Electrical TFN60RCP AC Disconnect Switches
For equipment grounding provision. #14 to 4 AWG, 60/75 deg Celsius, Cu/A1. An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance. Steel enclosure. 2-pole, 3-wire, 240 VAC, rated 10 hp. For central air conditioner. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. 4-3/4 x 7-1/2 x 2 in. UL1429 enclosure pullout switch, UL listed.
Cutler-Hammer DPF221RP AC Disconnect Switches Siemens EC3GB302 Ground Bar Kit With Terminal 2/0 Lug Square D QO200TRCP Molded Non-Fusible Disconnect Switch
An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance. For equipment grounding provision. #14 to 4 AWG, 60/75 deg Celsius, Cu/A1. Air conditioning disconnects from Schneider Electric are Underwriters Laboratories? (UL?) Listed NEMA Type 3R rainproof. They are designed to meet all current National Electrical Code? (NEC?) requirements for a disconnecting means on residential and commercial air conditioning installations, as well as other single-phase applications, such as swimming pools and pump houses.
Square D QO2L30SC Load Center Eaton BR24L70SP Load Center Cutler-Hammer AC222URNMP-A2 AC Disconnect Switches
Main lug load center, indoor, 30 A, 2 space/2 circuits. Accommodates both overhead and underground feed applications. 1 in maximum knockout on the top and bottom of the enclosure. Comes with a doorless surface mount cover and factory installed main lugs. UL listed. Load Centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. Single phase, 2 pole, 2 wire, 240 VAC. Rated 3 hp at 120 V, 10 hp at 240 V. For top and bottom entry and exit, with provision for type H conduit hub. Heavy-duty, high strength, rugged polymer enclosure with UV-resistant features. Swing-up cover remains in place when in open position, protective shield can be removed for access to fuses. No GB4 ground bar and No 360-011-24 pullout head replacement sold separately. #14-2 AWG wire range. 5 in x 8-5/8 in x 3-1/2 in. UL listed file No E5239.
   
 
1 2 3 ... 7