Plastic (snap-in) for type BR 1 in space. May also be used with 400 and 600 A load centers.
|
GE Filler Plate Kit, 6-7/8 in Length, 2-7/8 in Width, 3/4 in Height
|
For grounding copper or aluminum terminals in a GE load center. Offers 4 small holes for 14 to 8 AWG copper or 12 to 8 AWG aluminum terminals and 3 large holes for 14 to 4 AWG copper or 12 to 4 AWG aluminum terminals. UL listed and ANSI certified. 6-7/8 in H x 2-7/8 in W x 1/2 in depth, 0.105 lb.
|
|
|
|
|
|
|
|
|
|
|
|
|
For use with wire range 6-2/0. Can be mounted on any neutral or ground position by simply removing the termination screw. UL listed. 2-7/8 in H x 3/4 in W x 6-7/8 in D, 0.07 lb.
|
Cutler-Hammer Ground Bar Kit, 10 Terminals, 4.7 in Length, 2.3 in Width, 1/2 in Height
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
Fills opening in covers if twist out is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL listed and ANSI Certified.
|
Eaton Ground Bar Kit, Number of Terminals: 14, Wire Size: 14 to 4 AWG, 5.69 in L
|
Made for QO load centers. Field installed for number 12 to 2 Al or number 14 to 4 Cu wire. QO accessories can only be used with QO load centers.
|
|
|
|
|
|
|
|
|
|
|
|
|
Fills opening in covers if twist out is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL listed and ANSI Certified.
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
Used for additional grounding as required by local code. Compatible with most load center enclosures. Fits solid or stranded 4 - 14 copper wire and 10 - 12 aluminum wire. Includes mounting screws. UL listed and ANSI certified. 11 in H x 3-1/2 in W x 1/2 in D, 0.304 lb.
|
|
|
|
|
|
|
|
|
|
|
|
|
Breaker box neutral lug is designed for Homeline load centers. It works with number 1 to 1/0 copper and aluminum wire. UL listed and ANSI certified.
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
For equipment grounding provision. #14 to 4 AWG, 60/75 deg Celsius, Cu/A1.
|
|
|
|
|
|
|
|
|
|
|
|
|
Used for sealing off a hub opening when a service feed originates underground. The plate is compatible with A-type openings and can be used on outdoor devices that utilize a 4-hole mounting pattern. Use for A-size hub opening for Square D metering equipment. UL and CSA listed.
|
Siemens Closure Plate, 3/4 in Nominal, Dimensions: 12.8 X 5.2 X 3.7 in
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts one #14 - #4 copper wire or one #12 - #4 aluminum wire, two #14 - #12 copper wire or two #12 - #10 aluminum wire. ANSI certified and UL listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
For equipment grounding provision. #14 to 4 AWG, 60/75 deg Celsius, Cu/A1.
|
An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance.
|
Steel enclosure. 2-pole, 3-wire, 240 VAC, rated 10 hp. For central air conditioner. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. 4-3/4 x 7-1/2 x 2 in. UL1429 enclosure pullout switch, UL listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance.
|
For equipment grounding provision. #14 to 4 AWG, 60/75 deg Celsius, Cu/A1.
|
Air conditioning disconnects from Schneider Electric are Underwriters Laboratories? (UL?) Listed NEMA Type 3R rainproof. They are designed to meet all current National Electrical Code? (NEC?) requirements for a disconnecting means on residential and commercial air conditioning installations, as well as other single-phase applications, such as swimming pools and pump houses.
|
|
|
|
|
|
|
|
|
|
|
|
|
Main lug load center, indoor, 30 A, 2 space/2 circuits. Accommodates both overhead and underground feed applications. 1 in maximum knockout on the top and bottom of the enclosure. Comes with a doorless surface mount cover and factory installed main lugs. UL listed.
|
Main lug indoor load center, 70 A, 2 space/4 circuits. Maximum SCCR of 10,000 and a maximum load of 240 V. NEMA type 1 enclosure. Expandable load center capacity with the use of tandem or quad breakers. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Approved to only accept Canadian Homeline breakers.
|
An air conditioning disconnect (ACD) is a disconnect located between the load center and the air conditioner. Eaton's ACD provides an installer or repair personnel with a visible disconnecting means when performing maintenance.
|
|