Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE
Choose a sub category:
BUILDING WIRE / NM BUILDING WIRE / THHN BUILDING WIRE / UF
ENTRANCE CABLE ARMORED CABLE GROUND WIRE
LAMP CORD SJ CORD SPECIALTY WIRE
Sort By:
1 2 3 ... 8
Southwire 14GRN-SOLX500 Solid Single Building Wire Southwire 14BLUE-SOLX500 Solid Single Building Wire Southwire 14BLUE-STRX500 Stranded Single Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed.
Southwire 12RED-SOLX500 Tungsten Quartz Single Ended Building Wire Southwire 10BK-SOLX500 Solid Single Building Wire Southwire 12BLU-STRX500 Stranded Single Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed.
Southwire 10BLU-STRX500 Stranded Single Building Wire Southwire 12YEL-STRX500 Stranded Single Building Wire Romex SIMpull 28827472 Type NM-B Building Wire
Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code.
Coleman 946016618 Speaker Wire Barostat 553026607 Solid Type CL-2 Thermostat Cable Coleman 946036618 Speaker Cable
Parallel wire, power limited circuit cable, -20 Celsius to 105 Celsius. Used for stereos and hi-fi systems, home theater sound systems, lamps, and radios. Soft annealed copper per ASTM B3-90 conductor and PVC. UL Type CL2, UL1581 and UL13 approved. Clear jacket, on a spool. Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 degrees Celsius. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 volts. PVC insulation UL13 for power limited circuit cable for other than plenum, riser, or tray uses and UL1581 approved. Two bare copper conductors laid flat with integral PVC insulation and jacket. Clear jacket construction has one bare copper and one tinned copper conductor. Temperature rated from -20 to 60 degrees C, operating voltage 300 volts maximum. 18/2 stranded, flat, boxed. UL Standard 13 & 444, CSA C22.2 No. 214, NEC Article 725 & 800..
Romex SIMpull 14/2NM-WGX1000 Type NM-B Building Wire Romex SIMpull 28828272 Type NM-B Building Wire Coleman 5407 Bell Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Type CL2 low voltage cable using thermoplastic insulated solid conductors. Resistant to the spread of fire in accordance with NEC. Not for riser, plenum, or tray uses and 60 degrees Celsius. Use for thermostat control, burglar alarms, intercoms and doorbells. Soft annealed solid copper per ASTM B3-90 conductor. PVC insulation and UL13 approved for power limited circuit cable for other than plenum, riser, or tray uses. 150 volt.
Romex SIMpull 12/3NM-WGX1000FT Type NM-B Building Wire Barostat 553036607 Solid Type CL-2 Thermostat Cable Romex SIMpull 14/3NM-WGX1000FT Type NM-B Building Wire
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. 3 conductors, 1,000 foot spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 degrees Celsius. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 volts. PVC insulation UL13 for power limited circuit cable for other than plenum, riser, or tray uses and UL1581 approved. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. 3 conductors, 1,000 foot spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code.
Romex SIMpull 12/2NM-WGX1000 Type NM-B Building Wire Southwire 8SOLX500BARE Solid Electrical Wire Coleman 600006621 SPT-1 Lamp Cord
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Equipment and circuit grounding. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool.
Coleman 600006619 SPT-1 Lamp Cord Romex SIMpull 63946872 Type NM-B Building Wire Coleman 600006607 SPT-1 Lamp Cord
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool.
Coleman 600006608 SPT-1 Lamp Cord Coleman 553046607 Type CL-2 Electrical Wire Coleman 600006618 SPT-1 Lamp Cord
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 degrees Celsius. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 volts. PVC insulation UL13 for power limited circuit cable for other than plenum, riser, or tray uses and UL1581 approved. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool.
Coleman 600006601 SPT-1 Lamp Cord Coleman 601266607 SPT-2 Lamp Cord Southwire 6STRDX315BARE Stranded Electrical Wire
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Flexible and easily shaped, formed, welded and soldered into place. Use in overhead transmission and distribution systems and for grounding grid systems.
   
 
1 2 3 ... 8